logo

AMS MINI

AMS MINI

Application

  • medium size airport without category and category I. according to ICAO

Files for download

pdf Data Sheet (1.51 MB)

pdf Certificate MO AČR (580 KB)

pdf Certificate LÚ SR (395 KB)

pdf Certificate MAK (1.19 MB)

pdf Certificate SSGA (3.12 MB)

Description/Properties

  • well arranged control with use of push-buttons on touch-screen or by trackball
  • well arranged representation of information in several screens on one monitor
  • two inter-changeable working sites, where one works as master/workstation and the other one only as workstation
  • communication between working sites with use of the network LAN Ethernet (100 Base-T) up to the distance of 100 m or with use of WAN modems up to the distance of 3-15 km (depending on quality of the line)
  • remote control and monitoring of maximum nine airfield ground lighting systems in three or five degrees of luminous intensity
  • data transfer line for control and monitoring uses only one pair in communication cable
  • control and monitoring up to the distance of10 km
  • remote servicing supervision

System possibilities

  • AMS MINI  2 x DAP 128 TC
  • AMS MINI PLUS 4 x DAP 128 TC
  • control and monitoring of one landing runway (RWY)
  • control and monitoring of guidance systems (ALS) and elevated light (PAPI) from both directions
  • control and monitoring of maximum four taxiways (TWY)
  • direct connection to constant current regulators TCR.2 (Transcon)
  • connection of regulators made by other manufacturers with use of the rack SU-24B.RT with I/O modules RT-24
  • monitoring and control of the most important power systems with use of units PS-02
  • watching of objects and fire alarm
  • connection of meteorological system and representation of its data on the monitor
  • automatic setting of airfield ground lighting systems luminous intensity depending on runway visual range (RVR)
  • time synchronization with use of GPS system  
  • acoustic signalling of failure states; voice output in language of the user  
  • archiving of operational and failure states
  • in case of utilization of constant current regulators TCR.2  possibility of long-term monitoring of insulation state of serial circuits cables with use of well arranged diagrams
  • working sites embedded into the table TWS-01 or stand-alone working sites

02 02 03 mini schema

vcard


TRANSCON ELECTRONIC SYSTEMS, spol. s r.o.
Kvapilova 2133, CZ 738 01 Frýdek Místek
+420 558 437 551
+420 558 437 553
info@transcon.cz


VATIN: CZ26510634
lat=49.6686406
lon=18.3337659
File number: C 86718
registered with Municipal court in Prague
Data box: i6v74tw