TLI80
Application
- LED inset light, low protrusion 6,35 mm, sutaible for Runway (APP, ASR, END, THR, THREND, THRWB)
Files for download
TLI80-EN.pdfApplication
- APP - approach centre line and crossbar light
- ASR - approach side row light
- END - runway end light
- THR - treshold light
- THREND - threshold and runway end light
- THRWB - threshold and wing bar light
Classification
- FAA AC 150/5345-46; Class 2, Mode 1*, Style 3
- IEC TS 61827: Style 3, Size 3
*does not apply to 2,2 A powered lights
Accordance with
- Engineering Brief No. 67D
- IEC TS 61827
- ICAO Annex 14, Vol. I
- Figure: A1-1b, A2-1, A2-2, A2-3, A2-4, A2-8
- EASA CS-ADR-DSN
- Figure: U-1B, U-5, U-6, U-7, U-8, U-12
- TP-312
- Figure: A-1(b), B-1, B-2, B-3, B-4, B-B
Properties
- designed for simplicity and serviceability
- light diameter size 12'' (304 mm)
- easy winter mauntenece of the aerodrome thanks to 6,35 mm protrusion
- light depth in base 68 mm
- simple aluminium construction with stainless steel fasteners with a watertight IP68
- no negative slope before prisms
- non-glued, easily replaceble prisms
- velve for watertightness test
- only one type of prims for all light series TLI50, TLI80 and TLI81
- optical parts made of borosilicate glass
- operation with any CCR designed in accordance with IEC or FAA requirements
- excellent efficiency and colour characteristics due to the use of LED technology
- light output is variable as for halogen lamps, according to the requirements of Engieneering Brief No. 67D
- lifetime of least 110 000 h of operation
- efficient maintenance thanks to the common parts of the TLI50, TLI80, TLI81 series
- additional heating possible with ARC (arctit kit), according to the requirements of Engieneering Brief No. 67D
- monitoring function with function to disconect the light from the transformer (series loop) when LED failure is detected, according to the requrements of Engieneering Brief No. 67D
Resisted to
- temperature -55/+55 °C and thermal shock
- humidity, snow, ice and water, watertight IP68
- salt and UV radiation
- static and shear load, recurrent mechanical and hydraulic impact according to the iec ts 61827
- vibration 20/2 000 Hz with acceleration 10/15 G
- shock wave 10 kV on 5 kA, according to the requirements of Engieneering Brief No. 67D
- EMC ccording to the requirements of IEC 6100-6-2 and IEC 61000-6-4
Power source
- power cable with termination FAA AC 150/5345-26, L-823, Type II, Class A, Style 6
- isolation transformer 6,6 A or 2,2 A at the output from the secondary line (power of the isolating transformer according to the power input of the light)
Mounting
- bases for light, size 12'' (002 560, 002 561, 002 566, 002 567)
Mechanical parameters
- weight (of one pack) ± 7,4 kg