logo

TRP.1.X

TRP.1.X

Application

  • power supply for parallel lighting circuits

Files for download

pdf Data Sheet (1.64 MB)

pdf Certificates MO AČR (606 KB)

pdf Certificates LÚ SR (417 KB)

pdf Certificates SSGA (3.09 MB)

Certificate basis

  • ICAO - AERODROME DESIGN MANUAL - Part 5

Description/Properties

  • intended for use with lights of the series ML 121 HP and ML 124 H
  • air-cooled transformer 2,8 kVA
  • control by switches on distributor's front panel
  • regulation to 3 steps of intensity
  • possibility of control of up to 3 loops
  • outdoor execution
  • mounting on wall or supporting structure
  • remote and local control
  • remote signalling of operational and failure states
  • easy maintenance
  • economically advantageous for smaller lighting systems

Mechanical parameters

  • dimensions 600×800×300 mm
  • surface finish grey baking enamel colour RAL 7032
  • mass 80 kg

Elektrical parameters

  • supply voltage 208/220/230/240 V
  • tolerance of supply voltage +5 %/-10 %
  • frequency 50/60 Hz
  • nominal voltage of parallel distribution 230 V
  • voltage regulation 3 steps of intensity
  • output power 2,8 kVA
  • efficiency min 95 % at rated power
  • current (thermal) protection 120 % of rated power
  • number of controlled loops 1/2/3
  • max length of loop at load of 50–100 % (0,9–1,8 kVA) 100 m
  • max length of loop at load of to 50 % (0,9 kVA) 200 m

Operating conditions

  • protection (in working condition) IP 54
  • temperature range -35 (-55 optionally)/55 °C
  • storage temperature - 20/+ 50 °C
vcard


TRANSCON ELECTRONIC SYSTEMS, spol. s r.o.
Kvapilova 2133, CZ 738 01 Frýdek Místek
+420 558 437 551
+420 558 437 553
info@transcon.cz


VATIN: CZ26510634
lat=49.6686406
lon=18.3337659
File number: C 86718
registered with Municipal court in Prague
Data box: i6v74tw