Distributor TRS 10

Distributor TRS 10

Application

  • ensuring of uninterrupted power supply source for airport equipment

Files for download

pdf Data Sheet (2.38 MB)

pdf Certificate MAK (687 KB)

Certificate basis

  • airports in accordance with all ICAO categories

Description/Properties

  • automatic stand-in between mains supply sources and feeding from diesel generator sets
  • it feeds auxiliary distributors, which feed airport equipment, which requires uninterrupted power supply
  • upon the customer's wish it is possible to equip the distributor with any combination of one-, two- or three-phase outlets
  • montage on the steel stand
  • control and monitoring elements on the door
  • optional remote control and monitoring
  • it is equipped with PLC touch-screen display

Variants


4 individual inlets TRS 10.A 400 A, TRS 10.B 630 A, TRS 10.C 250A
  • two individual buses (BUS-A,
  • BUS-B), which serve as two individual, mutually backed inlets for individual devices
  • four individual 3-phase inlets
    • two mains inlets (NETWORK-A, NETWORK-B)
    • two inlets from diesel generator sets (DG-A, DG-B)
  • inlets NETWORK-A and DG-A go to the bus BUS-A, inlets NETWORK-B and DG-B to the bus BUS-B
  • a crosscut is between the buses BUS-A and BUS-B
  • front door contains panel with mnemonic diagram of signalling and control elements
3 individual inlets - TRS 10.D2 160 A
  • one bus (BUS)
  • three individual 3-phase inlets
    • two mains inlet (NETWORK)
    • one inlet from diesel generator sets (DG)
  • front door contains panel with mnemonic diagram of signalling and control elements 

Common parameters

  • voltage system 3PEN 50 Hz 230/400 V (220/380 V) TN-C-S
  • protection against dangerous contact with
  • exposed conductive parts automatic disconnection from source in the networks TN-C-S
  • synchronism factor  1,0
  • temperature range -5/+40 °C
  • resistance to vibrations 0,15 mm / 1–35 Hz
  • protection of closed distributor IP 43
  • protection of open distributor IP 00

Technical parameters

TRS 10.A TRS 10.B TRS 10.C TRS 10.D2
classification CAT I, CAT II, CAT III CAT I, CAT II, CAT III CAT I, CAT II, CAT III NO CAT
number of inlets 4 4 4 3
rated current [A] 400 630 250 160
weight [kg] ~730 ~1170 ~500 ~300
stand dimensions [mm] 3000×200×600 5200×200×600 1800×200×600 1200×200×400
dimensions without stand[mm] 3000×2000×650 5200×2000×650 1800×2000×650 1200×2000×450

Elektrical parameters of inlets

minimum duration of loss of voltage on the bus in case of switching between the inlets T1 = 200 ms (due to initialization of all connected devices)
time of presence of feeding mains for return from diesel generator sets to mains supply T2 = 5-600 sec (this time can be set by the user)
maximum duration of switching between two inlets T3 = 1 sec (maximum duration of power failure on the bus)
time  for evaluation of failure if the diesel generator sets do not start up T4 = 15 sec
tolerance of input voltage at individual inlets +10 % / -15 % (adjustable)
tolerance of input voltage frequency at individual inlets +10 % / -10 %