logo

TLI81

Application

  • LED inset lights 12'', low protrusion 6,35 mm, sutaible for Runway (RGL, RWY)

Files for download

TLI81.pdf

Application

  • RGL - runway guard lights (high intensity in configuration B)
  • RWY - runway edge lights (usable as stopway lights)

Classification

  • FAA AC 150/5345-46; Class 2, Mode 1*, Style 3
  • IEC TS 61827: Style 3, Size 3

Accordance with  

  • Engineering Brief No. 67D
  • IEC TS 61827
  • ICAO Annex 14, Vol. I
  • Figure: A1-1b, A2-9, A2-10, A2-20
  • EASA CS-ADR-DSN
  • Figure: U-1B, U-13, U-14, U-24
  • TP-312
  • Figure: A-1(b), B-9, B-10, B-17

Properties

  • designed for simplicity and serviceability
  • light diameter size 12''(304 mm)
  • easy winter maintenance of the aerodrome thanks to 6, 35 mm protrusion
  • light depth in shallow base 68 mm
  • simple aluminium construction with stainless steel fasteners with a watertight IP68
  • no negative slope before prisms
  • non-glued, easily replaceable prisms
  • velve for watertighness test
  • only one type of prism for all light series TLI50, TLI80, TLI81
  • optimal parts made of borosilicate glass
  • operation with any CCR designed in accordance with IEC or FAA requirement
  • exellent efficiency and colour characteristics due to the use of LED technology
  • light output is variable as for halogen lamps, according to the requirements of Engieneering Brief No. 67D
  • lifetime of at least 110 000 h operation
  • efficient mantenance thanks to the common parts of the light series TLI50, TLI80 and TLI81
  • additional heating possible with ARC (srtic kit), according to the requirements of Engieneering Brief No. 67D
  • optional MONITORING with function to disconnect the light from the transformer (series loop) when LED failure is detected, according to the requirements of Engineering Brief No. 67D

Resistance to

  • temperature -55 - +55 °C and thermal shock
  • humidity, snow, ice and water, watertight IP68
  • salt fog, solar and UV radiation
  • statistic and shear load, recurrent mechanical and hydraulic impact according to the IEC TS 61827
  • vibration 20 - 2 000 Hz with acceleration 10/15 G
  • shock wave 10 kV on 5 kA, according to the requierements of Engineering Brief No. 67D
  • EMC according to the requierements of IEC 61000-6-2 and IEC 61000-6-4

Power source

  • power lead with termination FAA AC 150/5345-26, L-823 Type II, Class A, Styke 6
  • isolation transformer 6,6 A or 2,2 A at the output from the secondary line (power of the isolating transformer according to the power input of the light)

Mounting

  • shallow bases, size 12'' (002 560, 002 561, 002 566, 002 567)

Mechanical parameters

  • weight (cardboard box) ± 7,4 kg
  • dimensions (cardboard box) 320x320x115 mm
vcard


TRANSCON ELECTRONIC SYSTEMS, spol. s r.o.
Kvapilova 2133, CZ 738 01 Frýdek Místek
+420 558 437 551
+420 558 437 553
info@transcon.cz


VATIN: CZ26510634
lat=49.6686406
lon=18.3337659
File number: C 86718
registered with Municipal court in Prague
Data box: i6v74tw