TLI50
Application
- LED inset light 8", low protrusion 6,35mm, suitable for Runway (EREX, RCL, REL, RETIL, RGL, SBLS, SBLC, TCLC, TCLS, TDZ, THL)
Files for download
Data Sheet.pdf
Application
- EREX - enhanced rapid exit taxiway centre line lights
- RCL - runway centre line lights
- RETIL - runway rapid exit taxiway indicator lights
- RGL - runway guard lights (low intensity in configuration B)
- SBLC - stop bar lights (curved section)
- SBLS - stop bar lights (straight section)
- TCLC - taxiway centre line lights (curved section)
- TCLS - taxiway centre line lights (straight section)
- TDZ - runway touchdown zone lights
- THL - runway take-off hold lights
Classification
- FAA AC 150/5345-46; Class 2, Mode 1*, Style 3
- IEC TS 61827: Styl 3, Size 3
*does not apply to 2,2 A poweredlights
Accordance with
- Engineering Brief No. 67D
- IEC TS 61827
- ICAO Annex 14, Vol. I
- Figure: A1-1b, A2-5, A2-6, A2-7 Cat. III, A2-12, A2-13, A2-14, A2-15, A2-16, A2-26
- EASA CS-ADR-DSN
- Figure: U-1B, U-9, U-10, U-11 Cat. III, U-16, U-17, U-18, U-19, U-20, U-29
- TP-312
- Figure: A-1(b), B-5, B-7 Cat III, B-12, B-14, B-24(a)
Properties
- designed for simplicity and serviceability
- light diameter size 8" (203)
- easy winter maintenance of the aerodrome thanks to 6,35 mm protrusion
- can be produced with two or four fixing holes
- light depth in shallow base 67 mm
- simple aluminium construction with stainless steel fasterners with a watertight IP68
- no negative slope before prisms
- non-glued, easily replecable prisms
- veleve for watertighness test
- only one type of prism all light series TLI50, TLI80 and TLI81
- optimal parts made of borosilicate glass
- operation with any colour charakteristics due to the use of LED technology
- light output is variable as for halogen lamps, according to the requirements of Engineering Brief No. 67D
- lifetime of at least 110 000h operation
- efficient maintenance thanks to the common parts of the light series TLI50, TLI80, TLI81
- additional heating possible with ARC (artic kit), according to the requirements of Engineering Brief No. 67D
- optional MONITORING with function to disconnect the light from transformer (series loop) when LED failure is detected, according to the requirements of Engineering Brief No. 67D
Resistence to
- temperature -55 - 55 °C and thermal shock
- humidity, snow, ice nad water, watertight IP68
- salt fog, solar and UV radiation
- static and shear load, recurrent mechanical and hydraulic impact according to the requirements of Engineering Brief No. 67D
- EMC according to the requirements of IEC 61000-6-2 and IEC 61000-6-4
Power source
- power cable with termination FAA AC 150/5345-26, L-823 Type II, Class A, Style 6
- isolating transformer 6,6A or 2,2A at the the output from the secondary line (power of the isolating transformer according to the power input of the light)
Mounting
- shallow bases, size 8" (002 562, 002 563)
- shallow bases, size 12" (002 560, 002 561) + adapter TIA1-F (8"/12")
Mechanical parameters
- weight (cardboard box) ± 3,2 kg
- dimensions (cardboard box) 250x250x115 mm