logo

TLI50

Application

  • LED inset light 8", low protrusion 6,35mm, suitable for Runway (EREX, RCL, REL, RETIL, RGL, SBLS, SBLC, TCLC, TCLS, TDZ, THL)

Files for download

Data Sheet.pdf

Application

  • EREX - enhanced rapid exit taxiway centre line lights
  • RCL - runway centre line lights
  • RETIL - runway rapid exit taxiway indicator lights
  • RGL - runway guard lights (low intensity in configuration B)
  • SBLC - stop bar lights (curved section)
  • SBLS - stop bar lights (straight section)
  • TCLC - taxiway centre line lights (curved section)
  • TCLS - taxiway centre line lights (straight section)
  • TDZ - runway touchdown zone lights
  • THL - runway take-off hold lights

Classification

  • FAA AC 150/5345-46; Class 2, Mode 1*, Style 3
  • IEC TS 61827: Styl 3, Size 3
        *does not apply to 2,2 A poweredlights

Accordance with

  • Engineering Brief No. 67D
  • IEC TS 61827
  • ICAO Annex 14, Vol. I
  • Figure: A1-1b, A2-5, A2-6, A2-7 Cat. III, A2-12, A2-13, A2-14, A2-15, A2-16, A2-26
  • EASA CS-ADR-DSN
  • Figure: U-1B, U-9, U-10, U-11 Cat. III, U-16, U-17, U-18, U-19, U-20, U-29
  • TP-312
  • Figure: A-1(b), B-5, B-7 Cat III, B-12, B-14, B-24(a)

Properties

  • designed for simplicity and serviceability
  • light diameter size 8" (203)
  • easy winter maintenance of the aerodrome thanks to 6,35 mm protrusion
  • can be produced with two or four fixing holes
  • light depth in shallow base 67 mm
  • simple aluminium construction with stainless steel fasterners with a watertight IP68
  • no negative slope before prisms
  • non-glued, easily replecable prisms
  • veleve for watertighness test
  • only one type of prism all light series TLI50, TLI80 and TLI81
  • optimal parts made of borosilicate glass
  • operation with any colour charakteristics due to the use of LED technology
  • light output is variable as for halogen lamps, according to the requirements of Engineering Brief No. 67D
  • lifetime of at least 110 000h operation
  • efficient maintenance thanks to the common parts of the light series TLI50, TLI80, TLI81
  • additional heating possible with ARC (artic kit), according to the requirements of Engineering Brief No. 67D
  • optional MONITORING with function to disconnect the light from transformer (series loop) when LED failure is detected, according to the requirements of Engineering Brief No. 67D

Resistence to

  • temperature -55 - 55 °C and thermal shock
  • humidity, snow, ice nad water, watertight IP68
  • salt fog, solar and UV radiation
  • static and shear load, recurrent mechanical and hydraulic impact according to the requirements of Engineering Brief No. 67D
  • EMC according to the requirements of IEC 61000-6-2 and IEC 61000-6-4

Power source

  • power cable with termination FAA AC 150/5345-26, L-823 Type II, Class A, Style 6
  • isolating transformer 6,6A or 2,2A at the the output from the secondary line (power of the isolating transformer according to the power input of the light)

Mounting

  • shallow bases, size 8" (002 562, 002 563)
  • shallow bases, size 12" (002 560, 002 561) + adapter TIA1-F (8"/12")

Mechanical parameters

  • weight (cardboard box) ± 3,2 kg
  • dimensions (cardboard box) 250x250x115 mm
 
vcard


TRANSCON ELECTRONIC SYSTEMS, spol. s r.o.
Kvapilova 2133, CZ 738 01 Frýdek Místek
+420 558 437 551
+420 558 437 553
info@transcon.cz


VATIN: CZ26510634
lat=49.6686406
lon=18.3337659
File number: C 86718
registered with Municipal court in Prague
Data box: i6v74tw