TI70
Application
- halogen inset light 12", standard protrusion 12,5 mm, suitable for APP, ASR, THR, THREND, END, RWY, RGL
Files for download
Light fixture function
- APP - approach centre line and crossbar light
- ASR - approach side row light
- THR - threshold light
- THREND - threshold and runway end light
- END - runway end light
- RWE - runway edge light
* usable as stopway light - RGL - high intensity runway guard light, configuration B
Classification
- FAA AC 150/5345-46: Class 2, Mode 1, Style 2
- IEC TS 61827: Style 3
Accordance with
- ICAO Annex 14, Vol. 1
Figure: A1-1a, A2-1, A2-2, A2-3/4, A2-8, A2-9/10, A2-20 - IEC TS 61827
- EASA CS-ADR-DSN
Figure: U-1, U-6, U-7/8, U-12, U-13/14, U-24 - TP312
Figure: B-1, B-2, B-3/4, B-8, B-9/10, B-17 - FAA AC 150/5345-46E*
L-850C, L-850D, L-852G
* photometrically compatible - АП-170, Том II
Properties
- standard protrusion: 12,5 mm
- size: diameter 304 mm (12")
- installation depth in base: 54 mm
- optimized optical parameters
- simple and durable aluminum design
- long-term optical stability due to the usage of
- cold mirror reflector lamps
- non-glued easily replaceable prisms
- effective maintenance due to many common parts with TI40, TI41, TI70, TI71 and TI72 series
Mechanical parameters
- weight (cardboard box) ~7,0 kg
- dimensions (cardboard box) 325×315×115 mm
Construction
- aluminium body - top part
- aluminium body - bottom part
- prism with gasket (sealing)
- lamp holder
- cold mirror reflector lamp
- dichroic filter
Resistance to
- temperature -55 ÷ +55 °C and thermal shock
- humidity, snow, ice and water, watertight IP68
- salt fog, solar and UV radiation
- static and shear load, recurrent mechanical and hydraulic impact according to the IEC TS 61827
- vibrations 20 ÷ 2 000 Hz with acceleration 10/15 G
Light source
- standard 50 mm diameter airfield cold mirror reflector halogen 6,6 A lamp
Power source
- isolating transformer with 6,6 A on secondary output (transformer power according to used lamp/lamps)